#1 - Erythrocyte phenotyping for feline AB system in domestic cats from the Ilhéus-Itabuna microregion, Bahia, Brazil

Abstract in English:

This study aimed to determine the erythrocyte phenotypes of the feline AB system and to check the presence of antigens other than those present in the feline AB system in domestic cats from Ilhéus-Itabuna microregion, Bahia, Brazil. Three-hundred feline blood samples were collected at the Veterinary Hospital of the “Universidade Estadual de Santa Cruz” (UESC) and in home visits to perform blood phenotyping using the tube-method testing. The reverse phenotyping was made between cats that tested phenotype B with blood samples of cats that tested phenotype A to confirm the blood phenotype B. The cross-tested among cats with phenotype A was made in order to verify the presence of different antigens of AB system in this blood phenotype. The results underwent macroscopic and microscopic analyses. Among the 300 animals tested, regarding breed, 290 were mixed-breed cats and among the remaining ten, five were Persians, four Siamese, and one Angora. 297 (99%) presented with phenotype A (including all the breeding cats) and three (1%) with phenotype B, and all this cats were mixed-breed cats. None (0%) of the cats showed the phenotype AB. All phenotype B bloods reacted to reverse phenotyping with phenotype A, confirming the phenotype B of these cats. All phenotype A bloods were compatible among each other, so no further erythrocyte antigens were detected through this test. The mother of one of the phenotype B cats was identified and had phenotype A, demonstrating phenotype A parents with phenotype B offspring. This finding indicates heterozygosis in the studied population. This data enable to conclude that the studied population presented different erythrocyte phenotypes, subsequently highlighting the importance of conducting phenotype analyses in these animals before performing blood transfusion to avoid serious hemolytic complications associated with incompatibility.

Abstract in Portuguese:

O objetivo deste estudo foi determinar a frequência dos fenótipos eritrocitários do sistema AB felino e verificar a presença de outros antígenos, não pertencentes ao sistema AB felino, em gatos domésticos das cidades de Ilhéus e Itabuna, Bahia, Brasil. Amostras de sangue de 300 gatos foram coletadas no Hospital Veterinário da Universidade Estadual de Santa Cruz (UESC) e em visitas domiciliares para realizar a fenotipagem sanguínea usando o método de tubo. A fenotipagem reversa foi realizada em gatos que testaram o fenótipo B com amostras que testaram o fenótipo A, para confirmação do fenótipo sanguíneo. O teste cruzado foi realizado entre gatos do fenótipo A, para pesquisar a presença de diferentes antígenos do sistema AB dentro desse fenótipo sanguíneo. Os resultados foram submetidos a análises macroscópicas e microscópicas. Dos 300 animais testados, 110 eram machos e 190 fêmeas, e suas idades variaram de cinco meses à 15 anos. Sobre as raças, 290 eram gatos sem raça definida e dos 10 restantes, cinco eram Persas, quatro eram Siameses e um Angorá. 297 (99%) apresentaram fenótipo A (incluindo todos os gatos de raça) e três (1%) tiveram fenótipo B, sendo todos esses gatos sem raça definida. Nenhum (0%) dos gatos apresentou fenótipo AB. Todos os sangues com fenótipo B reagiram na fenotipagem reversa com o fenótipo A, confirmando o fenótipo B desses gatos. Todos os sangues com fenótipo A foram compatíveis entre si, portanto nenhum antígeno eritrocitário adicional foi detectado através deste teste. A genitora de um dos gatos com fenótipo B, foi encontrada e a mesma possuía fenótipo A, demonstrando pais com fenótipo A e cria com fenótipo B. Esse achado indica heterozigose na população estudada. Esses dados levam à conclusão de que diferentes fenótipos eritrocitários estão presentes na população estudada e destacam a importância da realização de testes fenotípicos nesses animais antes dos procedimentos de transfusão, a fim de evitar complicações hemolíticas graves decorrentes do envolvimento de animais incompatíveis.


#2 - Monitoring and evaluation of the efficacy of whole blood and packed red cells transfusion in dogs, 30(8):665-669

Abstract in English:

ABSTRACT.- Morikawa M.K., Bochio M.M., Pincelli V.A., Freire R.L. & Pereira P.M. 2010. [Monitoring and evaluation of the efficacy of whole blood and packed red cells transfusion in dogs.] Monitoração e avaliação clínica da eficácia da transfusão de sangue total e concentrado de hemácias em cães. Pesquisa Veterinária Brasileira 30(8):665-669. Departamento de Clínicas Veterinárias, Universidade Estadual de Londrina, Campus Universitário, Cx. Postal 6001, Londrina, PR 86051-990, Brazil. E-mail: pmendes@uel.br Transfusion therapy has a great potential to save lives in small animals practice, and it has been used mainly in the emergency treatment for anemic animals, although this procedure is related to certain risks. A manner to minimize these risks is through keeping close monitoring during the time of transfusion, which furthermore allows an evaluation of recovering of the patient. The aim of the present research was to evaluate the efficacy of whole blood and packed red cells transfusions in anemic dogs. Seventy-seven transfusions in dogs have been done, 52 of whole blood and 25 of packed red cells, measuring (every 15-30 minutes) temperature, cardiac and breathing frequency, mucous tissue color and capillaries filling time throughout the procedure. The outcome shows that both compounds, may cause improvements to every assessed parameters 45 minutes from the start of the transfusion mainly to cardiac frequency, mucous tissue color and capillaries filling time (p<0.05). The success of a transfusion ensures apparent clinical improvement from two hours of the onset of the procedure.

Abstract in Portuguese:

RESUMO.- Morikawa M.K., Bochio M.M., Pincelli V.A., Freire R.L. & Pereira P.M. 2010. [Monitoring and evaluation of the efficacy of whole blood and packed red cells transfusion in dogs.] Monitoração e avaliação clínica da eficácia da transfusão de sangue total e concentrado de hemácias em cães. Pesquisa Veterinária Brasileira 30(8):665-669. Departamento de Clínicas Veterinárias, Universidade Estadual de Londrina, Campus Universitário, Cx. Postal 6001, Londrina, PR 86051-990, Brazil. E-mail: pmendes@uel.br A terapia transfusional tem grande potencial de salvar vidas na clínica de pequenos animais, e é usada principalmente na terapêutica de emergência em animais anêmicos, entretanto este procedimento está associado a vários riscos. Uma das formas de minimizá-los é pela monitoração constante durante a transfusão sanguínea, permitindo assim avaliar a melhora clínica do paciente. O objetivo deste trabalho foi avaliar a eficácia da transfusão de sangue total e de concentrado de hemácias em cães anêmicos, por meio da monitoração dos parâmetros vitais. Foram avaliadas 77 transfusões em cães, sendo 52 de sangue total armazenado e 25 de concentrado de hemácias. Durante todo o procedimento aferiu-se (a cada 15-30 minutos) a temperatura, frequência cardíaca, frequência respiratória e a coloração de mucosas dos pacientes, além do tempo de preenchimento capilar. Os resultados obtidos mostraram que ambos os componentes promoveram melhora dos parâmetros avaliados a partir de 45 minutos do início da transfusão sanguínea, principalmente da frequência cardíaca, coloração de mucosas e tempo de preenchimento capilar (p<0,05). A transfusão bem sucedida proporcionou melhora clínica aparente a partir de duas horas do início do procedimento.